AT-RPS8000 Quick Install Guide
5
Note
Ensure that air flow is unrestricted around the AT-RPS8000 unit.
4. Attach the provided DC power cord to the DC output connector on the
back panel of the AT-RPS8000 unit, directly behind the pre-installed
AT-PWR8000. (Refer to Figure 4 for the DC output connector.)
Figure 4
Back Panel of the AT-RPS8000 Unit
5. Connect the other end of the DC power cord to the R.P.S. Input
connector on the back panel of the Ethernet switch. (Refer to Figure 5
for the R.P.S. Input connector.)
Figure 5
Back Panel of the Ethernet Switch
6. Plug the AC power cord for the AT-RPS8000 into the AC connector on
the back panel of the unit. (Refer to Figure 4 for the AC connector.)
Note
The AT-RPS8000 unit and Ethernet switches should be connected to
power outlets on separate circuits. This will protect the switches from
a loss of power should a power circuit fail.
7. Plug the other end of the AC power cord into a wall outlet.
ON/OFF
DC Power Output Connector
AC Power Connector
Switch
R.P.S. Input Connector for the DC Power Cord