Allied-telesis AlliedView-EMS 3.10 DEVICE MANAGER Manuale Utente

Navigare online o scaricare Manuale Utente per Hardware del computer Allied-telesis AlliedView-EMS 3.10 DEVICE MANAGER. Allied Telesis AlliedView-EMS 3.10 DEVICE MANAGER User Manual [en] Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 133
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
AlliedView™-EMS 3.10 Device Manager User’s Guide Page 1 of 133
AlliedView™-EMS 3.10
(Full Installation)
DEVICE MANAGER USER’S GUIDE
Vedere la pagina 0
1 2 3 4 5 6 ... 132 133

Sommario

Pagina 1 - DEVICE MANAGER USER’S GUIDE

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 1 of 133 AlliedView™-EMS 3.10 (Full Installation) DEVICE MA

Pagina 2 - TABLE OF CONTENTS

2.1.3 SNMP Version The Device Manager can use SNMPv1, SNMPv2c and SNMPv3. You may specify a value of 1, 2 or 3. If the SNMP Version

Pagina 3

7.2.8 Close Closes the RMON Statistics window. 7 RMON AlliedView™-EMS 3.10 Device Manager User’s Guide Page 100 of 133

Pagina 4

7.3 History Control Table From the History Control Table menu, you can view RMON History information. Note - If there is a large

Pagina 5

RMON History Control Table window 7.3.1 Data Group Buttons At the RMON History Control Table window, you can view the history of

Pagina 6 - 1 Overview

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 103 of 133 Packet Type Shows the number of packets by the following types.

Pagina 7 - 2 Starting Device Manager

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 104 of 133 Owner Value of etherStatsOwner of the RMON Statistics group.

Pagina 8 - 2.1.1 Command Syntax

RMON History Entry tab 7.3.3.1 Available Control Table Entries This table shows all control table entries configured on the targe

Pagina 9 - 2.1.2 Target Host

Request Buckets The number of values which you asked the RMON agent to store. Granted Buckets The number of values the RMON agent

Pagina 10 - 2.1.6 Trap Community

Add Control Table Entry dialog box 7.3.3.4 Edit Button : changes the selected entry. To edit the entry, select an entry on the ta

Pagina 11 - 2.1.9 Security Level

RMON History Table tab 7.3.4.1 History Table The table shows history data for the selected control table entry. The table has the

Pagina 12 - 2.1.12 Privacy Protocol

7.3.4.2 Sort To sort table items, click a column title. When you click the column title, table items are sorted by the column in as

Pagina 13 - 2.1.14 Trap Version

the target host. If the string is not specified, the default community string "public" is used. If the Trap Community is

Pagina 14 - 2.1.15 Parameter File

RMON History Plot Chart tab 7.3.5.1 Popup Display You can see the exact value of a dot by moving the mouse cursor onto the dot. T

Pagina 15

Topics: • Popup Display RMON History Pie Chart tab 7.3.6.1 Popup Display To display the numeric value for a particular section

Pagina 16

Topics: • Polling Interval • Display Data Type of Chart • Regist Menu • Save Polling Data • Start Snapshot RMON Options

Pagina 17

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 113 of 133 Absolute Value Displays the sum of values which Device Manager g

Pagina 18

Note - Only the values of the collected RMON variables are saved. Values Device Manager calculates from these collected values are

Pagina 19

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 115 of 133 RMON History Control Parameters snapshot Below is a snapshot fro

Pagina 20

7.3.8 Close Closes the RMON History window. 7 RMON AlliedView™-EMS 3.10 Device Manager User’s Guide Page 116 of 133

Pagina 21 - 3 Main Window

7.4 Alarm Table From the Alarm Table menu, you can view and edit the RMON Alarm table on the RMON agent. RMON Alarm table is used

Pagina 22 - 3.1 Initial Window

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 118 of 133 Sampling Interval The time interval at which the RMON agent sam

Pagina 23 - 3.2 Panel Window

7.4.2 Event Table of Alarm "Event Table of Alarm" shows a list of events for the Alarm entry which is selected in the Ala

Pagina 24 - 3.2.5 Status Bar

-UserName AlliedView1 -SecLevel authNoPriv -AuthProtocol SHA -AuthPassword PASS1233 2.1.10 Authentica

Pagina 25 - 4 Basic Operations

Add Alarm Table Entry dialog box Alarm Index The index number used to identify this Alarm entry. By default, the lowest unused

Pagina 26 - 4.1 Click

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 121 of 133 Owner The owner (creator) of the Alarm entry. By default, "

Pagina 27

Index of the RMON Event entry which is triggered when the sampled value reaches the rising threshold. If you select "falling a

Pagina 28 - 4.3 Pop-up Menus

7.4.5 Remove Button : removes the selected Alarm entry. 7.4.6 Close Closes the window. 7 RMON AlliedView™-EMS 3.10 Device Manager

Pagina 29 - 4.4 Resizing Windows

7.5 Event Table From the Event Table menu, you can view and edit the RMON Event entries. The data is not automatically updated. U

Pagina 30 - 4.5 Resizing Tables

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 125 of 133 Add Event Table Entry dialog box The index number used to iden

Pagina 31 - Ex 1: After adjustment

7.5.4 Edit Button : edits the selected Event entry. Click this button to open the Edit dialog box for the selected entry. Change th

Pagina 32

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 127 of 133 RMON Event Log tab 7.6 Event Log From the Event Log menu, yo

Pagina 33

Event Index The index number of the Event table for this log entry. Index The index number used to identify this log entry. Log

Pagina 34 - 5 Common Menus

7.6.5 Display All Button : displays all event log entries. It may take some time to display all entries. 7.6.6 Refresh Button : dis

Pagina 35 - 5.1 File

devicemanager -TargetHost 172.16.99.123 -SnmpVersion 3 -UserName AlliedView -SecLevel authPriv -AuthP

Pagina 36

8 Forwarding Database The Forwarding Database option under the Bridge menu allows you to view the FDB (Forwarding Database) Table

Pagina 37

8.1 Standard View The Standard View allows you to view the FDB Table as returned by the device. This is the default view that is

Pagina 38

8.2 Enhanced View The Enhanced View allows you to select a port or group of ports to view its corresponding FDB Table entries. I

Pagina 39

USA Headquarters | 19800 North Creek Parkway | Suite 200 | Bothell | WA 98011 | USA | T: +1 800 424 4284 | F: +1 425 481 3895 European Headquarters |

Pagina 40 - 5.1.2 Reopen

Examples: devicemanager -TargetHost 172.16.99.123 -SnmpVersion 3 -UserName AlliedView -SecLevel noAuthNoPriv -TrapVe

Pagina 41 - 5.1.5 Exit

2.2 Starting From a Network Management Application Device Manager can be started from an integrated network management applicatio

Pagina 42 - 5.2 View

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 16 of 133 Starting from SNMPc 2.2.1 Starting From Castle Rock SNMPc To sta

Pagina 43 - 5.2.4 Threshold

2.2.2 Starting From HP OpenView Network Node Manager To start Device Manager from HP OpenView, select a node on the map window, the

Pagina 44 - 5.2.5 Current Log

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 18 of 133 firmware v1.0.2 in the network. Use the LAN IP address of the de

Pagina 45 - 5.2.6 Snapshot

2.2.3 Starting From IBM Tivoli NetView To start Device Manager from Tivoli NetView, select the device that you want to connect to

Pagina 46 - 5.2.7 Refresh

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 2 of 133 TABLE OF CONTENTS 1 OVERVIEW...

Pagina 47 - 5.3 Option

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 20 of 133 Starting from WhatsUp 2.2.4 Starting From Ipswitch WhatsUp To sta

Pagina 48

3 Main Window When started, Device Manager displays one of the following windows, depending on how it is started. Topics: • Initi

Pagina 49 - Tab Type

3.1 Initial Window If the target host is not specified, or specified SNMP settings don't match those configured on the host,

Pagina 50 - 5.3.2 External Command Tab

3.2 Panel Window When the target host is specified and Device Manager can identify the host model, the following window appears.

Pagina 51 - 5.3.3 User Action Tab

3.2.1 System Name Usually, the System Name is set to a unique descriptive name for identifying the device. This refers to the MIB o

Pagina 52

4 Basic Operations This chapter describes the basic operations within Device Manager windows. Topics: • Click • OK, Cancel and

Pagina 53

4.1 Click Device Manager uses both the left and right mouse buttons. To operate items on the menu bar, you can use both the left

Pagina 54 - 5.3.4 Other Tab

4.2 OK, Cancel and Set Buttons Dialog boxes have buttons to commit or discard changes made in the dialog box. Clicking the OK but

Pagina 55

4.3 Pop-up Menus Some elements such as network ports also act as menus. When you right click on a port, a pull-down menu appears.

Pagina 56

4.4 Resizing Windows To resize a window, follow the procedures specific to the platform you use. The new window size is stored wh

Pagina 57 - 5.4 Tool

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 3 of 133 5.2.1 Toolbar ...

Pagina 58 - 5.4.5 QoS Manager

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 30 of 133 Ex 1: Before adjustment 4.5 Resizing Tables Device Manager di

Pagina 59 - 5.5 User Menu

Ex 1: After adjustment AlliedView™-EMS 3.10 Device Manager User’s Guide Page 31 of 133

Pagina 60 - 5.5.2 Edit

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 32 of 133 Ex 2: After adjustment Example 2: Adjusting the boundary betwee

Pagina 61

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 33 of 133 Ex 3: After adjustment

Pagina 62 - 5.5.3 Common

5 Common Menus This chapter describes the menu items common to all Allied Telesis managed devices. Topics: • File • View • Op

Pagina 63 - 5.5.4 Target

5.1 File The File menu lets you start and stop managing a device, check the properties of the target host, or exit Device Manager

Pagina 64 - 5.6 Help

Select Target Host dialog box Target host The host name or the IP address of the target host. To see the description of the host,

Pagina 65 - 5.6.3 License Registration

AlliedView™- Page 37 of 133 EMS 3.10 Device Manager User’s Guide Settings If the Version is set to "v1" or "v2c&qu

Pagina 66 - 5.6.4 About

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 38 of 133 User Account Name This is the SNMPv3 User Account to be used for

Pagina 67 - 6 MIB Variable Window

AlliedView™- 133 EMS 3.10 Device Manager User’s Guide Page 39 of Polling Options dialog box Privacy Password If the Security Lev

Pagina 68 - MIB Variable Window

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 4 of 133 6.4.5 Clear Button ...

Pagina 69 - 6.1 Table Tab

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 40 of 133 Polling Interval Device Manager sends a GetRequest to the SNMP ag

Pagina 70 - 6.1.1 Transpose Button

5.1.3 Close Closes the SNMP session with the device and closes the Panel window. To connect to another device, select File > Ope

Pagina 71 - 6.2 Plot Chart Tab

5.2 View Using the View menu, you can determine whether or not to display the Device Manager toolbar and status bar, view and set

Pagina 72 - 6.2.4 Clear Button

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 43 of 133 Display Threshold 5.2.3 System Info Toggles display of system i

Pagina 73 - 6.2.5 Reverse Button

Add button (Green 'plus' icon) Adds a new threshold definition. Remove button (Blue 'X' icon) Removes the se

Pagina 74 - 6.3 Bar Chart Tab

5.2.6 Snapshot Clicking this option in the View menu opens the Start Snapshot window. Use this window to create an image of the dev

Pagina 75 - 6.3.5 Reverse Button

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 46 of 133 Selection PNG File Plot chart snapshot_p#.png Bar Chart sna

Pagina 76

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 47 of 133 Screen tab 5.3 Option In the Option menu, general preferences

Pagina 77 - 6.4 Edit Tab

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 48 of 133 Look & feel Changes how Device Manager windows are displayed

Pagina 78

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 49 of 133 Tab Type Displays each stacked device in a separate tab.

Pagina 79 - 6.4.9 Threshold Button

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 5 of 133 7.6.2 Event Log Entry ...

Pagina 80

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 50 of 133 Resize window when the number of stack changes When checked, De

Pagina 81 - 6.5 Options Tab

External Command tab 5.3.3 User Action Tab In the User Action tab, you can specify the action to take when an event occurs. There

Pagina 82 - 6.5.4 Save Polling Data

User Action tab You can choose an action for each event type. There are two types of actions. Popup message Device Manager displa

Pagina 83 - 6.5.5 Start Snapshot

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 53 of 133 $CURRENT Current value of the variable. $MAXVALUE Highest valu

Pagina 84 - 6.5.6 Default Button

$VALUEn The value of the nth MIB object sent with the trap, where n is a number in the range 1 to 9. 5.3.4 Other Tab In the Othe

Pagina 85

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 55 of 133 System Location "MIB variable" option displays a MIB

Pagina 86 - 7.1 RMON-specific Buttons

SNMP send data encoding Specifies the character encoding of the data sent by the device. Your options are None, Shift JIS, JIS, and

Pagina 87 - 7.2 Statistics

5.4 Tool From the Tool menu, you can launch external applications such as Telnet, your WEB browser, the MIB browser AMIGO, or VLA

Pagina 88 - 7.2.1 Data Group Buttons

5.4.2 WEB Browser Starts the web browser specified in the External Command tab of the Options dialog box (Option > Option > E

Pagina 89 - 7.2.3 Entry Tab

5.5 User Menu In the User Menu, you can create, edit and execute user-defined menu items. This function may be useful if there a

Pagina 90

1 Overview Device Manager is a device management application that lets you manage Allied Telesis' hubs, switches and routers

Pagina 91 - 7.2.3.4 Edit Button

User-defined menu items can be classified as either 'Common' or 'Target-specific'. Menu items in the 'Com

Pagina 92 - 7.2.4.1 Sort

Displays MIB variables of your choice in the common GUI window. Note - It takes times to get values for many variables. To impro

Pagina 93 - 7.2.4.2 Reset Table Button

MIB set External command Executes the specified command line. External command 5.5.3 Common The Common submenu contains the u

Pagina 94 - 7.2.5.1 Popup Display

5.5.4 Target The Target submenu contains the user-defined menu items which are accessible only when connected to the specific targe

Pagina 95 - 7.2.6.1 Popup Display

5.6 Help From the Help menu, you can view the online user's manual, license information and version information for Device M

Pagina 96 - 7.2.7.1 Polling Interval

5.6.3 License Registration Device Manager can be evaluated for a limited period without a license. If you want to use Device Manage

Pagina 97 - 7.2.7.5 Start Snapshot

5.6.4 About Displays version and copyright information for Device Manager. 5 Common Menus AlliedView™-EMS 3.10 Device Manager User

Pagina 98 - Start snapshot

6 MIB Variable Window When you select a menu item to view information from the SNMP agent, a MIB variable window with tabs appear

Pagina 99 - RMON Statistics snapshot

MIB Variable Window 6 MIB Variable Window AlliedView™-EMS 3.10 Device Manager User’s Guide Page 68 of 133

Pagina 100 - 7.2.8 Close

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 69 of 133 Table tab 6.1 Table Tab In the Table tab, MIB variables are di

Pagina 101 - 7.3 History Control Table

2 Starting Device Manager Device Manager can be started in two ways, from the command line or from a network management applicati

Pagina 102 - 7.3.1 Data Group Buttons

6.1.1 Transpose Button : flips rows and columns. 6 MIB Variable Window AlliedView™-EMS 3.10 Device Manager User’s Guide Page 70 o

Pagina 103 -

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 71 of 133 Plot Chart tab 6.2 Plot Chart Tab In the Plot Chart tab, varia

Pagina 104 - 7.3.3 Entry Tab

The components of the Plot Chart tab are discussed below. 6.2.1 Graph The left half of the window contains the graph showing the va

Pagina 105

6.2.5 Reverse Button : flips the states of all checkboxes, that is, unchecks all variables currently selected and checks all variab

Pagina 106 - 7.3.3.3 Add Button

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 74 of 133 Bar Chart tab 6.3 Bar Chart Tab The Bar Chart tab displays var

Pagina 107 - 7.3.3.5 Remove Button

AlliedVi: flips the states of all checkboxes, that is, unchecks all variables currently selected and checks all variables currently

Pagina 108 - 7.3.4.1 History Table

Note - Displaying many variables at the same time imposes a load on system resources. If you encounter delay or reduced system per

Pagina 109 - 7.3.4.3 Reset Table Button

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 77 of 133 Edit tab 6.4 Edit Tab In the Edit tab, you can change the valu

Pagina 110 - 7.3.5.1 Popup Display

In the Edit tab, variables are shown in a table. The table has the following columns (fields) for each entry. 6.4.1 Checkbox Column

Pagina 111 - 7.3.6.1 Popup Display

6.4.7 Get MIB Value Button : Updates the MIB Value fields of the selected variables. To select a variable, click the MIB Variable f

Pagina 112 - 7.3.7.1 Polling Interval

2.1 Starting From the Command Line The command line interface is the most basic way to start Device Manager. Topics: • Command S

Pagina 113 - 7.3.7.4 Save Polling Data

Edit Threshold Item dialog box The MIB Variable field shows the selected variable name. To set a threshold, enter a threshold valu

Pagina 114 - 7.3.7.5 Start Snapshot

6.5 Options Tab In the Options tab, preferences specific to the MIB variable windows can be changed. Topics: • Polling Interval

Pagina 115

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 82 of 133 6.5.2 Display Data Type of Chart Specifies how to display data on

Pagina 116 - 7.3.8 Close

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 83 of 133 Start snapshot Save polling data 6.5.5 Start Snapshot Clicking

Pagina 117 - 7.4 Alarm Table

MIB Variables snapshot 6.5.6 Default Button : Reset all options to default settings. 6 MIB Variable Window AlliedView™-EMS 3.10

Pagina 118

7 RMON The RMON (Remote network MONitoring) facility collects management information from remote monitoring agents. Monitoring age

Pagina 119 - 7.4.3 Add Button

7.1 RMON-specific Buttons The RMON window is slightly different from the MIB variable windows. The RMON window has several tabs a

Pagina 120

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 87 of 133 RMON Statistics window 7.2 Statistics From the Statistics men

Pagina 121

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 88 of 133 7.2.1 Data Group Buttons In the RMON Statistics window, you can v

Pagina 122 - 7.4.4 Edit Button

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 89 of 133 Note - Items calculated by Device Manager always have the descr

Pagina 123 - 7.4.6 Close

SNMP Trap community string. This is used when receiving Traps from agents. DisplayName Titlebar string. UserName User account n

Pagina 124 - 7.5 Event Table

RMON Statistics Entry tab 7.2.3.1 Available Control Table Entries This table shows all control table entries configured on the t

Pagina 125 - 7.5.3 Add Button

Status The status of the control entry. Owner The owner (creator) of the control entry. 7.2.3.2 Select Button : changes the c

Pagina 126 - 7.5.6 Close

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 92 of 133 RMON Statistics Table tab 7.2.3.5 Remove Button : removes the s

Pagina 127 - 7.6 Event Log

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 93 of 133 RMON Statistics Plot Chart tab items in descending order. To re

Pagina 128 - 7.6.4 Remove Button

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 94 of 133 7.2.5.1 Popup Display You can see the exact value of a plotted do

Pagina 129 - 7.6.7 Close

RMON Statistics 3-D Pie Chart tab 7.2.6.1 Popup Display When you move the mouse cursor onto a section of the pie chart, the value

Pagina 130 - 8 Forwarding Database

RMON Options tab (Statistics) 7.2.7.1 Polling Interval You can change the polling interval here. 7.2.7.2 Display Data Type of Char

Pagina 131 - 8.1 Standard View

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 97 of 133 Note - Calculated values are rounded. For example, Number of Erro

Pagina 132 - 8.2 Enhanced View

Start snapshot AlliedView™-EMS 3.10 Device Manager User’s Guide Page 98 of 133

Pagina 133

AlliedView™-EMS 3.10 Device Manager User’s Guide Page 99 of 133 RMON Statistics snapshot Below is a snapshot from the RMON Stati

Commenti su questo manuale

Nessun commento