Start-up Sequence
Software Reference for x310 Series Switches
3.14 AlliedWare Plus
TM
Operating System - Version 5.4.4C C613-50046-01 REV A
There are three possible status results displayed for each module loaded - OK, INFO,
ERROR:
■ OK means that the module has loaded correctly.
■ INFO means that an error occurred, but the device is usable.
■ ERROR means that an error occurred and device operation may be affected.
Additional specific information accompanies an INFO or ERROR status result. For example,
if a corrupt release file was set as the startup release, the following error message would
be seen:
Whether an error message results in a case of the device being unusable will depend on
the specific error and message, so will need to be dealt with on a case by case basis. If a
software release has been corrupted, as shown on start-up, a new release may need to be
loaded.
Bootloader 1.0.9 loaded
Press <Ctrl+B> for the Boot Menu
Reading filesystem...
Error: Release filename is invalid (should be x310-5.4.4C.rel)
Error: There is no backup release file set
Error: Boot failed. Please recover the system using the Boot Menu
Restarting...Bootloader 1.0.9 loaded
Press <Ctrl+B> for the Boot Menu
Commenti su questo manuale