353
Maximum MST
Instances
31 1 - 31
Bridge Priority
32768 0 - 61440
Region Name
MAC Address of
AT-GS950/24 switch
-
Region Revision
0 0 - 65535
Dynamic Path Cost
Calculation
True True/False
Bridge Maximum Age
20 Seconds 6 - 40 Seconds
Bridge Forward Delay
15 Seconds 4 - 30 Seconds
Maximum Hop Count
20 6 - 40
Transient Hold Count
31 - 10
MSTP Instance ID
none 1 - 31
Mapped VLAN
none
-
Path Cost 20000 1 - 200,000,000
Priority 128 0 - 240, 16 steps
PointToPoint Status Auto
Auto/ForceTrue/ForceFalse
Edge Port False
True/False
MSTP Status Enable Enable/Disable
Protocol Migration False
True/False
Table 9. AT-S109 Version 1.1.0 Management Software Default Settings (Continued)
Parameter
AT-GS950/24
Default Setting
Specifications