Pagina 1 - AT-FS724L

AT-FS724LFast Ethernet SwitchInstallation GuidePN 613-50464-00 Rev A

Pagina 2

Overview2Key FeaturesThe AT-FS724L switch has the following key features: 24 10/100Base-TX ports System and port LEDs Auto MDI/MDI-X on all ports

Pagina 3 - Statement

AT-FS724L Fast Ethernet Switch Installation Guide3Status LEDsTable 2 lists the status LEDs for the AT-FS724L switch.Table 2 Status LEDsTwisted Pair P

Pagina 4

Overview4Duplex ModeDuplex mode refers to the way an end-node sends and receives data on the network. An end-node can operated in either half- or full

Pagina 5 - Table of Contents

AT-FS724L Fast Ethernet Switch Installation Guide5the port on the switch automatically configures itself as MDI-X. This feature allows you to use eith

Pagina 6

Overview6This timer will delete a MAC address from the table if it does not see a frame from the end-node with the address on any port after five minu

Pagina 7 - Welcome to Allied Telesyn

AT-FS724L Fast Ethernet Switch Installation Guide7Internal Power SupplyThe AT-FS724L uses a universal internal switching power supply operating at 100

Pagina 8 - Contacting Allied Telesyn

Overview8Network TopologiesThe AT-FS724L switch can be used in a variety of network topologies, such as a power workgroup or cascade. Both topologies

Pagina 9 - Overview

AT-FS724L Fast Ethernet Switch Installation Guide9Cascade TopologyConnecting two similar networking devices together is called ‘cascading’. Figure 3 i

Pagina 11 - Twisted Pair Ports

11Chapter 2InstallationVerifying the Package ContentsMake sure the following items are included in your package. If any item is missing or damaged, co

Pagina 12 - Auto MDI/MDI-X

Copyright © 2003 Allied Telesyn, Inc.960 Stewart Drive, Suite B, Sunnyvale, CA 94085, USAAll rights reserved. No part of this publication may be repro

Pagina 13 - MAC Address Table

Installation12Planning the InstallationBe sure to observe the following guidelines when planning the installation of your switch.❑ The end-nodes conne

Pagina 14 - Backpressure and Flow Control

AT-FS724L Fast Ethernet Switch Installation Guide13Reviewing Safety GuidelinesPlease review the following safety guidelines before you begin to instal

Pagina 15 - Internal Power Supply

Installation14Installing the Switch on a Table or DesktopIf you are rackmounting an AT-FS724L switch, refer to “Rackmounting the Switch” on page 15. T

Pagina 16 - 100 Mbps

AT-FS724L Fast Ethernet Switch Installation Guide15Rackmounting the SwitchThe AT-FS724L switch can be used on a desktop or installed in a rack. For de

Pagina 17 - Cascade Topology

Installation164. Secure the switch to the rack using 2 screws (not provided) for each side as shown in Figure 7.Figure 7 Installing the Switch to the

Pagina 18

AT-FS724L Fast Ethernet Switch Installation Guide17Warranty RegistrationWhen you finish installing the product, you should register you product by com

Pagina 20 - Planning the Installation

19Chapter 3TroubleshootingFollow the guidelines below to test and troubleshoot the installation in the event a problem occurs.If the POWER LED is OFF,

Pagina 22

21Appendix ATechnical SpecificationsPhysicalDimensions: W x D x H11.6 in x 7.8 in x 1.72 in)Weight: 2.5 kg (5.5 lbs)EnvironmentalMaximum Operating: 0°

Pagina 23 - Rackmounting the Switch

iiiElectrical Safety and Emission Compliance StatementStandards: This product meets the following standards.U.S. Federal Communications CommissionDecl

Pagina 24

Technical Specifications22Electrical RatingInternal Universal Power Supply: 100 - 240 V AC, 50/60 Hz, 0.5A inputAgency ComplianceEMI/RFI: FCC Class B,

Pagina 25 - Warranty Registration

AT-FS724L Fast Ethernet Switch Installation Guide23Pinout AssignmentsFigure 8 shows the pin assignments of the RJ-45 connector.Figure 8 RJ-45 Connect

Pagina 27 - Troubleshooting

25Appendix ATranslated Safety and Emission InformationImportant: This appendix contains multiple-language translations for the safety statements in th

Pagina 28

Translated Safety and Emission Information26Standards: This product meets the following standards:U.S. Federal Communications CommissionDeclaration Of

Pagina 29 - Technical Specifications

AT-FS724L Fast Ethernet Switch Installation Guide27 1RFI Emission FCC Class B, EN55022 Class B, VCCI Class B, C-TICK 2 Warning: In a domestic enviro

Pagina 30 - Agency Compliance

Translated Safety and Emission Information28Normen: Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen. 1 Hochfrequenzstörung FCC Klas

Pagina 31 - Pinout Assignments

AT-FS724L Fast Ethernet Switch Installation Guide29Standarder: Dette produkt tilfredsstiller de følgende standarder. 1Radiofrekvens forstyrrelsesemis

Pagina 32

Translated Safety and Emission Information30Eisen: Dit product voldoet aan de volgende eisen. 1RFI Emissie FCC Klasse B, EN55022 Klasse B, VCCI Klass

Pagina 33 - Appendix A

AT-FS724L Fast Ethernet Switch Installation Guide31Normes: Ce produit est conforme aux normes de suivantes. 1 Emission d'interférences radioélec

Pagina 34

Electrical Safety and Emission Compliance StatementivRFI Emission FCC Class B, EN55022 Class B, VCCI Class B, C-TICK  1Warning: In a domestic environ

Pagina 35

Translated Safety and Emission Information32Standardit: Tämä tuote on seuraavien standardien mukainen. 1 Radioaaltojen häirintä FCC Luokka B, EN55022

Pagina 36

AT-FS724L Fast Ethernet Switch Installation Guide33Standard: Questo prodotto è conforme ai seguenti standard. 1 Emissione RFI (interferenza di radiof

Pagina 37

Translated Safety and Emission Information34Sikkerhetsnormer: Dette produktet tilfredsstiller følgende sikkerhetsnormer. 1 RFI stråling FCC Klasse B,

Pagina 38

AT-FS724L Fast Ethernet Switch Installation Guide35Padrões: Este produto atende aos seguintes padrões. 1 Emissão De Interferência De Radiofrequência

Pagina 39 - : DANGER D’ÉLECTROCUTION

Translated Safety and Emission Information36Estándares: Este producto cumple con los siguientes estándares. 1Emisión RFI FCC Clase B, EN55022 Clase B

Pagina 40

AT-FS724L Fast Ethernet Switch Installation Guide37Standarder: Denna produkt uppfyller följande standarder. 1Radiostörning FCC Klass B, EN55022 Klass

Pagina 42

vTable of ContentsElectrical Safety and Emission Compliance Statement ...iiiTable of Contents ...

Pagina 43

Table of ContentsviChapter 3Troubleshooting ...19Appendix ATe

Pagina 44

viiThis guide contains instructions on how to install the AT-FS724L Fast Ethernet Switch.Where to Find Related GuidesThe Allied Telesyn web site at ww

Pagina 45

Welcome to Allied TelesynviiiContacting Allied Telesyn This section provides Allied Telesyn contact information for technical support as well as sales

Pagina 46

1Chapter 1OverviewThe AT-FS724L is Fast Ethernet switch that provides simple, cost-effective solutions for switching between 10 Mbps and 100 Mbps.The