613-001394 Rev. Ax600 Series Layer 3 Gigabit Ethernet Switchesx600-24Tsx600-24Ts/XPx600-48Tsx600-48Ts/XPx600-24Ts-POEx600-24Ts-POE+Installation Guide
Tables10
Chapter 5: Troubleshooting100Cannot Establish a Local (Out-of-Band) Management SessionIf you are unable to establish a local (out-of-band) management
x600 Layer 3 Gigabit Ethernet Switch Installation Guide101Switch Functions IntermittentlyIf a switch functions intermittently, check the system hardwa
Chapter 5: Troubleshooting102Issues with Virtual Stacking Chassis ConfigurationFor information on issues with stacking, refer to the Allied Telesis In
103Appendix ATechnical SpecificationsPhysical SpecificationsDimensions (H x W x D):x600-24Ts 44 mm x 440 mm x 305 mm(1.72 in. x 17.34 in. x 12.0 in.)x
Appendix A: Technical Specifications104Environmental SpecificationsOperating Temperature: 0° C to 40° C (32° F to 104° F)Storage Temperature: -25° C t
x600 Layer 3 Gigabit Ethernet Switch Installation Guide105CertificationsEMI (Emissions): FCC Class A, ICES-003 Class A, EN55022 Class A,EN61000-3-2, E
Appendix A: Technical Specifications106RJ-45 Twisted Pair Port PinoutsFigure 49 illustrates the pin layout of an RJ-45 connector and port.Figure 49. R
x600 Layer 3 Gigabit Ethernet Switch Installation Guide107Table 15 lists the pin signal definitions when a port operating at 1000 Mbps.Table 15. Pin S
Appendix A: Technical Specifications108RJ-45 Style Serial Terminal Port PinoutsTable 16 lists the pin signal definitions on the RJ-45 style serial ter
x600 Layer 3 Gigabit Ethernet Switch Installation Guide109Table 17 lists the RPS 17-pin D-combo port and connector pinout definitions.Table 17. AT-RPS
11PrefaceThis guide contains the installation instructions for the x600 Series Layer 3 Gigabit Ethernet Switches. This preface contains the following
Appendix A: Technical Specifications110AT-RPS3204 21-pin D-combo Port and Connector PinoutsFigure 51 illustrates the pin layout of the RPS 21-pin D-co
x600 Layer 3 Gigabit Ethernet Switch Installation Guide11115 Ground16 Ground17 Ground18 +12.0 VDC sense19 Ground20 No connectA-1 +12.0 VDCTable 18. AT
Appendix A: Technical Specifications112
Preface12Product DocumentationFor overview information about the software features of the AlliedWare Plus Operating System Software which runs on the
x600 Layer 3 Gigabit Ethernet Switch Installation Guide13Starting a Management SessionFor instructions that describe how to start a local management s
Preface14Safety Symbols Used in this DocumentThis document uses the safety symbols defined in Table 1.Table 1. Safety SymbolsSymbol Meaning Descriptio
x600 Layer 3 Gigabit Ethernet Switch Installation Guide15Where to Find Web-based GuidesThe product documentation for all Allied Telesis products are a
Preface16Contacting Allied TelesisThis section provides Allied Telesis contact information for technical support as well as sales and corporate inform
17Chapter 1 OverviewThis chapter contains the following sections: “Introduction” on page 18 “Switch Descriptions” on page 19 “10/100/1000Base-T Por
Chapter 1: Overview18IntroductionThe x600 Series Switches are managed Gigabit Ethernet switches that act as standalone units. There are six Basic Laye
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide19Switch DescriptionsThe following sections describe the x600 Series Layer 3 Gigabit E
Copyright © 2010 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied
Chapter 1: Overview20x600-24Ts/XPSwitchThe x600-24Ts/XP switch has the following hardware features: 24 10/100/1000Base-T ports Four Gigabit Ethernet
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide21x600-48Ts Switch The x600-48Ts switch has the following hardware features: 44 10/10
Chapter 1: Overview22x600-48Ts/XPSwitchThe x600-48Ts/XP switch has the following hardware features: 44 10/100/1000Base-T ports Four Gigabit Ethernet
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide23x600-24Ts-POE The x600-24Ts-POE switch has the following hardware features: 24 10/1
Chapter 1: Overview24x600-24Ts-POE+ The x600-24Ts-POE+ switch has the following hardware features: 24 10/100/1000Base-T ports with Power over Etherne
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide2510/100/1000Base-T PortsThis section describes the 10/100/1000Base-T ports on the swi
Chapter 1: Overview26Cable Type The cabling requirements for a 10/100/1000Base-T port are: For 10 Mbps operation: Standard TIA/EIA 568-B-compliant Ca
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide27SFP Transceiver SlotsAll of the x600 Series switches feature slots for four optional
Chapter 1: Overview28XFP Transceiver SlotsThe x600-24Ts/XP and the x600-48Ts/XP Switches have two slots for optional XFP 10 Gigabit Ethernet transceiv
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide29Combo PortsThe 10/100/1000Base-T ports 21R to 24R are paired with the four SFP slots
3Electrical Safety and Emissions StandardsThis product meets the following standards.RFI Emissions FCC Class A, EN55022 Class A, EN61000-3-2, EN61000-
Chapter 1: Overview30SD Card SlotAll of the x600 Series Switches have an SD card slot for storing configuration files and AlliedWare Plus Operating Sy
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide31Port LEDsThe following sections describe the 10/100/1000Base-T port, SFP, and XFP LE
Chapter 1: Overview32Figure 13 shows the port LEDs for x600-24Ts-POE and x600-24Ts-POE+ switches. These LEDs are separated from the 10/100/1000Base-T
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide33SFP LEDs There is one LINK/ACTIVITY LED for each SFP slot. The SFP LEDs for the x600
Chapter 1: Overview34Figure 15. SFP LEDs - x600-48 Port SwitchXFP TransceiverSlot LEDsEach 10 Gigabit Ethernet transceiver slot on the x600-24Ts/XP an
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide35Table 5. XFP Slot LEDLED Function State DescriptionL/A Link Status and ActivityOff N
Chapter 1: Overview36System STATUS LEDsThe system status LEDs on the front panel display general status information. To locate these LEDs, see Figure
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide37STACK LEDsThe STACK LEDs reflect the link status of the two stack ports on the AT-St
Chapter 1: Overview38Table 7. STACK LEDsLED State DescriptionMSTR Off The switch is not part of a stack or is a member unit of the stack.Solid GreenTh
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide39Secure Digital (SD) LEDAll x600 series switches have one Secure Digital (SD) LED sho
4Translated Safety StatementsImportant: The symbol indicates that a translation of the safety statement is available in a PDF document titled “Trans
Chapter 1: Overview40Terminal PortThe terminal port is used to establish a local (out-of-band) management session with the switch. You establish a loc
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide41Power Over Ethernet (PoE and PoE+)The following section applies to x600-24Ts-POE and
Chapter 1: Overview42PoE Power is injected on the Ethernet cabling along with data by Power Sourcing Equipment (PSE), like an Ethernet LAN switch or r
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide43Differencesbetween PoE,PoE+ andEnhanced PoEThere are three major differences between
Chapter 1: Overview44Power Classes Once a PD is discovered, a PSE may optionally perform PD classification by applying a DC voltage to the port. If th
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide45PSU installed in the x600-24Ts-POE. This means that you can connect powered devices
Chapter 1: Overview46Redundant Power SuppliesThe RPS connector on an x600 Series switch rear panel can connect to an optional Redundant Power Supply m
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide47AT-LBM (Loop Back) ModuleThe x600-48Ts/XP switch is shipped from the factory with an
Chapter 1: Overview48VCS Stacking ModuleA Virtual Chassis Stack (VCS) is a group of x600 Layer 3 Gigabit Ethernet Series switches with a VCS Stacking
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide49AC Power ConnectorThe x600 switches have a single AC power supply socket on the rear
5ContentsPreface ...
Chapter 1: Overview50
51Chapter 2: Virtual Chassis StackingThis chapter contains the following sections: “VCStackTM Introduction” on page 52 “Features of VCStacking” on p
Chapter 2: Virtual Chassis Stacking52VCStackTM IntroductionA Virtual Chassis Stack (VCStack) is a group of physically separate switches that are conne
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide53VCS Stacking Modules, Cables, and ConnectionsThe stacks are connected via the stacki
Chapter 2: Virtual Chassis Stacking54Ring ConfigurationA virtual stack using x600 switches can comprise up to 4 stack members connected in a ring topo
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide55Table 10. State Change TableEvent on Master NodeReaction on MasterReaction on Stack
Chapter 2: Virtual Chassis Stacking56Resiliency LinkConfigurationsvia Switch PortsTwo resiliency-link configurations that connect to switch ports are
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide57Resilient StackedTopologyWhere network connectivity uptime is a major criteria, you
Chapter 2: Virtual Chassis Stacking58Stack FormationA virtual chassis stack (VCS) always contains a master plus a number of stack members. To be part
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide59NoteThe ability to independently set both a stack member’s priority and its ID means
Contents6VCS Stacking Module...
Chapter 2: Virtual Chassis Stacking60management VLAN ID and IP address, use the SHOW STACK command.Stack Member IdentificationWhen a switch becomes a
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide61Running QoS within a VCS stackIn general you can apply the same principles when conf
Chapter 2: Virtual Chassis Stacking62VCS FailureRecoveryIf the stack master fails or is removed, the other stack members decide which of two actions t
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide63StackMaintenanceAn operational stack configuration may require occasional maintenanc
Chapter 2: Virtual Chassis Stacking64detected. This situation results in the re-election of one stack master and the re-integration of the stack into
65Chapter 3Installing the HardwareThis chapter provides procedures to install an x600 switch. The chapter contains the following sections: “Reviewing
Chapter 3: Installing the Hardware66Reviewing Safety PrecautionsPlease review the following safety precautions before you begin to install the switche
x600 Layer 3 Gigabit Ethernet Switch Installation Guide67All Countries: Install product in accordance with local and National Electrical Codes. E8Ci
Chapter 3: Installing the Hardware68Caution: The unit does not contain field serviceable components. Please return damaged units for servicing.Caution
x600 Layer 3 Gigabit Ethernet Switch Installation Guide69Unpacking a SwitchTo unpack a switch, perform the following procedure:1. Remove all component
7Figure 1. x600-24Ts Switch...
Chapter 3: Installing the Hardware70Installing the Power Cord Retaining ClipPerform the following procedure to install the power cord retaining clip o
x600 Layer 3 Gigabit Ethernet Switch Installation Guide71Installing the Switches in an Equipment RackPerform the following procedure to install each s
Chapter 3: Installing the Hardware725. Install the second rack-mount bracket on the other side of the switch with the four remaining screws.6. Mount t
x600 Layer 3 Gigabit Ethernet Switch Installation Guide73Resetting the SwitchYou may need to reset the switch after upgrading the firmware or after yo
Chapter 3: Installing the Hardware74VC Stacking Module InstallationOverview When you are preparing the x600 switches for a VC Stack configuration, the
x600 Layer 3 Gigabit Ethernet Switch Installation Guide75Installing theAT-StackXGModuleTo install the AT-StackXG module, perform the following procedu
Chapter 3: Installing the Hardware76CautionDo not force AT-StackXG module into place. Doing so may damage the connector pins on the backplane inside t
x600 Layer 3 Gigabit Ethernet Switch Installation Guide77NoteDo not cable AT-StackXG module until you have prepared the switch’s Alliedware Plus Opera
Chapter 3: Installing the Hardware78
79Chapter 4Cabling the Network PortsThis chapter contains the instructions for attaching network cables to an x600 switch. The chapter contains the fo
Figures8
Chapter 4: Cabling the Network Ports80Twisted Pair and Fiber Optic SpecificationsTwisted PairCableSpecificationsTable 12 lists the cabling specificati
x600 Layer 3 Gigabit Ethernet Switch Installation Guide81SFP/XFPTransceiverSpecificationsThe specifications for an optional SFP or XFP transceiver can
Chapter 4: Cabling the Network Ports82Installing SFP/XFP TransceiversReview the following guidelines before installing an optional SFP or XFP transcei
x600 Layer 3 Gigabit Ethernet Switch Installation Guide832. Remove the transceiver from its shipping container and store the packaging material in a s
Chapter 4: Cabling the Network Ports846. For the x600-48Ts and x600-48Ts/XP switches, verify that handles on the top two SFP modules are in the up pos
x600 Layer 3 Gigabit Ethernet Switch Installation Guide85Installing an XFPTransceiverTo install an XFP transceiver in an x600 switch, perform the foll
Chapter 4: Cabling the Network Ports865. Repeat this procedure to install a second XFP transceiver or go to “Cabling the 10/100/1000Base-T and Fiber O
x600 Layer 3 Gigabit Ethernet Switch Installation Guide87Cabling the 10/100/1000Base-T and Fiber Optic PortsObserve the following guidelines when conn
Chapter 4: Cabling the Network Ports88Powering on a SwitchTo power on a switch, perform the following procedure:1. Position the power cord retaining c
x600 Layer 3 Gigabit Ethernet Switch Installation Guide893. Connect the other end of the power cord to an appropriate AC power outlet. For power speci
9Table 1. Safety Symbols ...
Chapter 4: Cabling the Network Ports903. Configure the terminal or terminal emulation program as follows: Baud rate: Default is 9600 bps (Range is 96
x600 Layer 3 Gigabit Ethernet Switch Installation Guide91Warranty RegistrationFor warranty information and registration, go to the Allied Telesis web
Chapter 4: Cabling the Network Ports92
93Chapter 5TroubleshootingThis chapter contains information about how to troubleshoot a switch in the event a problem occurs. Sections in the chapter
Chapter 5: Troubleshooting94Power LED is OffCheck the PWR LED on the front of the switch. If the LED is off, indicating that the unit is not receiving
x600 Layer 3 Gigabit Ethernet Switch Installation Guide95Twisted Pair Port Link LED is OffWhen a twisted pair port on the switch is connected to a pro
Chapter 5: Troubleshooting96SFP or XFP LED is OffWhen a fiber optic port on the switch is connected to a properly operating end node, the Link LED for
x600 Layer 3 Gigabit Ethernet Switch Installation Guide97Transceiver is Installed but the Status is “Not Present”If a SFP or XFP transceiver is instal
Chapter 5: Troubleshooting98System Fault LED is BlinkingA blinking FAULT LED indicates that the switch is updating the active boot configuration file
x600 Layer 3 Gigabit Ethernet Switch Installation Guide99System Fault LED is Steadily OnIf the system FAULT LED is steadily on, a problem has occurred
Commenti su questo manuale